Fire Alarm Products

Leading Manufacturers, Exporters and Wholesaler of Addressable Fire Alarm System and Conventional Fire Alarm System from Udaipur.

Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Current Consumption Standby 0.6mA, Alarm: 1.0mA
Input Voltage 24 VDC [16V to 28V]
Dimension / LWH 108 mm x 86 mm x 38 mm
Humidity 0 to 95% Relative Humidity, Non condensing
Indicator Status Normal: Single blink / Active: Steady / Fault: Double Blink
Ingress Protection Rating IP30
Input Relay Normally Open dry contact
Input Resistance 5.1Kohms / ¼ W
Material / Colour ABS / White Glossy finishing
Operating Temperature -10°C to +50°C
Protocol / Addressing Private, Value range from 1 to 254
Weight 155g (with Base), 85g (without Base)

Click to view more

Preferred Buyer From

Location Worldwide

The PY-IM-101-A Addressable Input Module is used to acknowledge normally open monitor signals from interface equipment and then send a communication signal to the control panel, ideally for monitoring sprinkler system, pressure switch, position switch, signal valves, and other third party equipment such as conventional panel.

The unit is manufactured based on the requirement of EN 54 part 18, European Standard. The unit is aesthetically pleasing with an unobtrusive design that will complement modern building designs and its plug-in type assembles make installation and maintenance more convenient to the installer. The unit incorporates an intelligent processor that provides automatic monitoring for both open and short circuits of the input signal line. The PY-IM-101-A Input Module is compatible with the PY-CP-4A Analogue Intelligent Fire Alarm Control Panel, produced by single manufacturer PEPL, to avoid addressable communication compatibility problems.

Features
  • Loop powered device
  • LED status indicator
  • Input cable monitored
  • Normally open configuration
  • Aesthetically pleasing design
  • Fire or Supervisory signal configuration
  • Built-in MCU processor and digital addressing
  • Surface mounting with fix base for simple installation

 

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier
Type Auto Dialer Alarm Fire Panel
Country of Origin India
AC Power AC220V±10% 50Hz, 2.0 Amps.
Using environment Temperature 0°C~50°C Related Humidity= 95% (40±2°C)
Fire & Fault Contact Outputs 1.0 amps DC24V or AC125V
Standby Current 65mA @ DC24V
Zone Capacity Can Be Connected with 30 Fire Detectors and Infinite Manual Call Points
Dimension (L x W x H) 265×335×87 mm
Battery Maintenance Free Dry Batteries, Max. Charger Capacity- 4ah Battery
Total 24 V System Power 3.0 amps

Click to view more

Preferred Buyer From

Location Worldwide

Conventional Fire Alarm Control Panel is a 24volt, 2 or 4 zones, Class B, Conventional Fire Alarm Control Panel. It is designed exclusively to meet the latest market requirements and microprocessor technology, with stand-by batteries. It has functions of operation indication, fault indication, alarm indication, and cable checking for short circuits or broken circuit.

Features
  • One set each of volt free changeover contacts operable on fire and fault.
  • Class change input for remote control.
  • Zone and alarm disablement.
  • 28V 125mA fused supply permanently available.
  • 28V 300mA fused supply available for fire alarm bells or sounders.
  • Passive repeater available.

 

Read More...


Yes! I am interested


Enquiry Now


Looking for Product Name ?

Close

Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us